| RFx ID : | 35221458 |
| Tender Name : | Main contractor or Roofer for roof repairs, roof replacement, minor window joinery and cladding replacement at Rotorua Boys High School |
| Reference # : | 263031 |
| Open Date : | Tuesday, 20 October 2026 9:30 AM (Pacific/Auckland UTC+13:00) |
| Close Date : | Tuesday, 17 November 2026 4:00 PM (Pacific/Auckland UTC+13:00) |
| Department/Business Unit : | Board of Trustees - Approve by BoT - ie. School Principal |
| Tender Type : | Request for Tenders (RFT) |
| Tender Coverage : | Sole Agency [?] |
| Categories : |
|
| Regions: |
|
| Exemption Reason : | None |
| Required Pre-qualifications : | None |
| Contact : |
All communication must take place through GETS Q&A function |
| Alternate Physical Delivery Address : | All submissions to be made through the GETS website |
| Alternate Physical Fax Number : |
Site overview attached at document 6. Document 7; site specific plans to be loaded as NTT week starting 19/10/2026
i. Roof of Block A – Undertake ridge resealing, skylight and chimney flashing replacement, full roof re-screwing, fixing remediation and associated roof maintenance works to improve weather-tightness and roof performance.
ii. Roof of Block B – Undertake replacement of rusted roof fixings and deteriorated downpipes, resealing of ridge and flashing joins, and associated roof maintenance works to restore weather-tightness.
iii. Roof of Block C – Replace rusted roof fixings and supply and install the missing barge flashing to improve weather-tightness and roof performance.
iv. Roof, cladding and joinery of Block G – Undertake roof, cladding, window joinery, drainage and safety remediation works as identified in the MoE Construction Advisor’s report.
v. Roof of Block N – Undertake apron flashing resealing and replacement/remediation of the deteriorated fascia to restore weather-tightness and maintain building fabric integrity.
vi. Roof of Block S – Undertake replacement of failed roofing, insulation, gutters, flashings and fixings, including full replacement of the internal membrane gutter and associated remediation works.
vii. Roof of Block T – Undertake replacement of the deteriorated roof areas, flashings, insulation, gutters and spouting, together with resealing and repair of the internal membrane gutter, with no works required to the roof section currently in good condition.
viii. Roof of Block X4 – Undertake full roof replacement, including substrate repairs, insulation, flashings, gutters and spouting, reinstatement of affected internal linings, and relocation of rooftop A/C inverter units where practicable.